ifpanimated2.gif (127617 bytes)  Home Up Feedback Contents SearchYour one stop supplier-the intumescent distributor    

Fire Rated Boards

 

Performance Benefits
Comprehensively tested and assessed in accordance with BS476 part 20: 1987 for up to 4 hours fire resistance
Ease of installation - dry trade
Lightweight
Simple retro-fitting of aditional services
Tested for acoustic performance
firerated.jpg (25471 bytes)
Introduction

IFP Fire Rated Boards are designed to prevent the spread of fire from one compartment to another where mechanical and electrical services penetrate separating walls and floors, and provide up to 4 hours fire resistance IFP Fire Rated Boards consist of a high density mineral fibre slab which is factory pre-coated with a water based, fire resistant coating. When used in conjunction with IFP fire rated coating and mastic, the boards provide an effective fire barrier for large multiple-service openings.

Performance

When exposed to the heat of a fire, the excellent thermal insulation properties of IFP Fire Rated boards provide an effective barrier, preventing the passage of fire and elevated temperatures. The fire resistant coating and mastic seal around services and board joints provide a further barrier to the passage of cold smoke.

Application

IFP Fire Rated Boards are suitable for use in any building which has single or multiple services penetrating fire rated compartment walls and floors Typical types of building where IFP Fire Rated Boards are commonly used are Retail Stores and Shopping Centres, Communication and Broadcasting facilities, Commercial Buildings, Power Stations and Control Rooms. IFP Fire Rated Boards can be used in walls or floors. (For installation details please refer to technical data sheet)

Specification

Supply and install IFP Fire Rated Boards to provide up to (1, 2, 3 or 4) hours fire resistance to all floor/wall openings. Installation to be in accordance with the manufacturers recommendations.

Fire Rated Coating and Mastic

The use of IFP Fire Rated Coating and Mastic is an essential element in the performance of the system. The mastic provides an ideal medium for filling the small gaps between cables, pipes etc. thus contributing to the effectiveness of the fire and smoke sealing performance. The Fire Rated Coating is used to coat the services, the edges of all openings, and the cut edges of the Fire Rated Boards to ensure that the system is adequately bonded together and to the substrate so as to form an effective fire barrier.

Non Standard manufacturing and Testing

IFP products can be manufactured to meet project specific requirements where standard production specifications may not fulfil all a client needs. For example, size and fixing variations can be accommodated, and special design facilities are available. Project specific fire testing can be arranged for particular site configurations

All the above products, where relevant, are tested to British Standards 478: Parts 8, 20, 22 and 31.1

 

Home ] Up ]

Send mail to enquiry@ifpsl.com with questions or comments about this web site.
Copyright © 1999 INTUMESCENT FIRE PROTECTION SUPPLIES LTD
Last modified: October 04, 2001